EMC1423/EMC1424 - 1°C Temperature Sensor with Hardware Thermal Shutdown Datasheet - SMSC

/var/www/html/datasheet/sites/default/files/pdfhtml_dummy/1423_1424-html.html
background image

SMSC EMC1423/EMC1424

DATASHEET

Revision 2.0 (08-10-12) 

Datasheet

PRODUCT FEATURES

EMC1423/EMC1424 

1°C Temperature Sensor with 
Hardware Thermal Shutdown

General Description

The EMC1423 and EMC1424 are high accuracy, low 
cost, System Management Bus (SMBus) temperature 
sensors. Advanced features such as Resistance Error 
Correction (REC), Beta Compensation (to support CPU 
diodes requiring the BJT/transistor model including 
45nm, 65nm and 90nm processors) and automatic 
diode type detection combine to provide a robust 
solution for complex envir onmental  monitoring 
applications. 

Additionally, the EMC1423 and EMC1424 provide a 
hardware programmable system shutdown feature that 
is programmed at part power-up via two pull-up resistor 
values and that cannot be masked or corrupted through 
the SMBus.

Each device provides ±1° accuracy for external diode 
temperatures and ±2°C accuracy for the internal diode 
temperature. The EMC1423 monitors three temperature 
channels (two external and one internal). The EMC1424
monitors four temperature channels (three external and 
one internal). 

Resistance Error Correction automatically eliminates the 
temperature error caused by series resistance allowing 
greater flexibility in routing thermal diodes. Beta 
Compensation eliminates temperature errors caused by 
low, variable beta transistors common in today's fine 
geometry processors. The automatic beta detection 
feature monitors each external diode/transistor and 
determines the optimum sensor settings for accurate 
temperature measurements regardless of processor 
technology. This frees the user from providing unique 
sensor configurations for each temperature monitoring 
application. These advanced features plus ±1°C 
measurement accuracy provide a low-cost, highly 
flexible and accurate solution for critical temperature 
monitoring applications.

Applications

„

Notebook Computers

„

Desktop Computers

„

Industrial 

„

Embedded applications

Features

„

Hardware Thermal Shutdown

triggers dedicated SYS_SHDN pin

hardware configured range 77°C to 112°C in 1°C steps

cannot be disabled or modified by software

„

Support for diodes requiring the BJT/transistor model

supports 45nm, 65nm, and 90nm CPU thermal diodes.

„

Automatically determines external diode type and 

optimal settings

„

Resistance Error Correction

„

External Temperature Monitors

±1°C Accuracy (60°C < T

DIODE

 < 100°C)

0.125°C Resolution

Supports up to 2.2nF diode filter capacitor

Anti-parallel diodes for extra diode support

„

Internal Temperature Monitor

±2°C accuracy

„

3.3V Supply Voltage

„

Programmable temperature limits for ALERT 

„

Available in Small 10-pin MSOP Lead-free RoHS 

Compliant Package

/var/www/html/datasheet/sites/default/files/pdfhtml_dummy/1423_1424-html.html
background image

Ordering Information:

EMC1423-1-AIZL-TR FOR 10-PIN, MSOP LEAD-FREE ROHS COMPLIANT PACKAGE

EMC1424-1-AIZL-TR FOR 10-PIN, MSOP LEAD-FREE ROHS COMPLIANT PACKAGE

Note: See 

Table 1.1, "Part Selection"

 for SMBus addressing options.

REEL SIZE IS 4,000 PIECES.

This product meets the halogen maximum concentration values per IEC61249-2-21

For RoHS compliance and environmental information, please visit 

www.smsc.com/rohs

Please contact your SMSC sales representative for additional documentation related to this product 
such as application notes, anomaly sheets, and design guidelines.

1°C Temperature Sensor with Hardware Thermal Shutdown

Datasheet

Revision 2.0 (08-10-12)

2

SMSC EMC1423/EMC1424

 

DATASHEET

Copyright © 2012 SMSC or its subsidiaries. All rights reserved.

Circuit diagrams and other information relating to SMSC products are included as a means of illustrating typical applications. Consequently, complete information sufficient for 
construction purposes is not necessarily given. Although the information has been checked and is believed to be accurate, no responsibility is assumed for inaccuracies. SMSC 
reserves the right to make changes to specifications and product descriptions at any time without notice. Contact your local SMSC sales office to obtain the latest specifications 
before placing your product order. The provision of this information does not convey to the purchaser of the described semiconductor devices any licenses under any patent 
rights or other intellectual property rights of SMSC or others. All sales are expressly conditional on your agreement to the terms and conditions of the most recently dated 
version of SMSC's standard Terms of Sale Agreement dated before the date of your order (the "Terms of Sale Agreement"). The product may contain design defects or errors 
known as anomalies which may cause the product's functions to deviate from published specifications. Anomaly sheets are available upon request. SMSC products are not 
designed, intended, authorized or warranted for use in any life support or other application where product failure could cause or contribute to personal injury or severe property 
damage. Any and all such uses without prior written approval of an Officer of SMSC and further testing and/or modification will be fully at the risk of the customer. Copies of 
this document or other SMSC literature, as well as the Terms of Sale Agreement, may be obtained by visiting SMSC’s website at http://www.smsc.com. SMSC is a registered 
trademark of Standard Microsystems Corporation (“SMSC”). Product names and company names are the trademarks of their respective holders. 

SMSC DISCLAIMS AND EXCLUDES ANY AND ALL WARRANTIES, INCLUDING WITHOUT LIMITATION ANY AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY, 
FITNESS FOR A PARTICULAR PURPOSE, TITLE, AND AGAINST INFRINGEMENT AND THE LIKE, AND ANY AND ALL WARRANTIES ARISING FROM ANY COURSE 
OF DEALING OR USAGE OF TRADE. IN NO EVENT SHALL SMSC BE LIABLE FOR ANY DIRECT, INCIDENTAL, INDIRECT, SPECIAL, PUNITIVE, OR CONSEQUENTIAL 
DAMAGES; OR FOR LOST DATA, PROFITS, SAVINGS OR REVENUES OF ANY KIND; REGARDLESS OF THE FORM OF ACTION, WHETHER BASED ON CONTRACT; 
TORT; NEGLIGENCE OF SMSC OR OTHERS; STRICT LIABILITY; BREACH OF WARRANTY; OR OTHERWISE; WHETHER OR NOT ANY REMEDY OF BUYER IS HELD 
TO HAVE FAILED OF ITS ESSENTIAL PURPOSE, AND WHETHER OR NOT SMSC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.

/var/www/html/datasheet/sites/default/files/pdfhtml_dummy/1423_1424-html.html
background image

1°C Temperature Sensor with Hardware Thermal Shutdown

Datasheet

SMSC EMC1423/EMC1424

3

Revision 2.0 (08-10-12)

 

DATASHEET

Table of Contents

Chapter 1

Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

1.1

Part Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7

Chapter 2

Pin Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Chapter 3

Electrical Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

3.1

Absolute Maximum Ratings  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11

3.2

Electrical Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12

3.3

SMBus Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13

Chapter 4

System Management Bus Interface Protocol  . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

4.1

System Management Bus Interface Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  14

4.2

Write Byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  15

4.3

Read Byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  15

4.4

Send Byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  15

4.5

Receive Byte. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  15

4.6

Alert Response Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16

4.7

SMBus Address  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16

4.8

SMBus Timeout  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16

Chapter 5

Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

5.0.1

Conversion Rates  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  18

5.0.2

Dynamic Averaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

5.1

SYS_SHDN Output. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

5.2

Hardware Thermal Shutdown Limit  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  20

5.3

ALERT Output  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  21
5.3.1

ALERT Pin Interrupt Mode  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  21

5.3.2

ALERT Pin Comparator Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  21

5.4

ALERT and SYS_SHDN Pin Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  21

5.5

Beta Compensation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  22

5.6

Resistance Error Correction (REC)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  22

5.7

Programmable External Diode Ideality Factor  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

5.8

Diode Faults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  23

5.9

Consecutive Alerts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  23

5.10

Digital Filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  23

5.11

Temperature Monitors  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  25

5.12

Temperature Measurement Results and Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  25

5.13

Anti-parallel Diode Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  26

5.14

External Diode Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  26

Chapter 6

Register Description  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

6.1

Data Read Interlock  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  31

6.2

Temperature Data Registers  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  31

6.3

Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  32

6.4

Configuration Register  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  32

6.5

Conversion Rate Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  33

6.6

Limit Registers  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  34

6.7

Scratchpad Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  35

6.8

Therm Limit Registers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  36

6.9

External Diode Fault Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  36

/var/www/html/datasheet/sites/default/files/pdfhtml_dummy/1423_1424-html.html
background image

1°C Temperature Sensor with Hardware Thermal Shutdown

Datasheet

Revision 2.0 (08-10-12)

4

SMSC EMC1423/EMC1424

 

DATASHEET

6.10

Software Thermal Shutdown Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  37

6.11

Hardware Thermal Shutdown Limit Register  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

6.12

Channel Mask Register  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  38

6.13

Consecutive ALERT Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  39

6.14

Beta Configuration Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  40

6.15

External Diode Ideality Factor Registers  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  41

6.16

High Limit Status Register  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  43

6.17

Low Limit Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  43

6.18

THERM Limit Status Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  44

6.19

Filter Control Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  44

6.20

Product ID Register  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  45

6.21

SMSC ID Register (FEh)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  45

6.22

Revision Register (FFh) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  46

Chapter 7

Typical Operating Curves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

Chapter 8

Package Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

8.1

Package Markings  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  50

Chapter 9

Datasheet Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

/var/www/html/datasheet/sites/default/files/pdfhtml_dummy/1423_1424-html.html
background image

1°C Temperature Sensor with Hardware Thermal Shutdown

Datasheet

SMSC EMC1423/EMC1424

5

Revision 2.0 (08-10-12)

 

DATASHEET

List of Figures

Figure 1.1 EMC1423/EMC1424 Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Figure 2.1 EMC1423/EMC1424 Pin Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   9
Figure 4.1 SMBus Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  14
Figure 5.1 System Diagram for EMC1423  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  17
Figure 5.2 System Diagram for EMC1424  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  18
Figure 5.3 Block Diagram of Hardware Thermal Shutdown  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  20
Figure 5.4 Isolating ALERT and SYS_SHDN Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  22
Figure 5.5 Temperature Filter Step Response  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  24
Figure 5.6 Temperature Filter Impulse Response. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   24
Figure 5.7 Block Diagram of Temperature Monitoring Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  25
Figure 5.8 Diode Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  27
Figure 8.1 10-Pin MSOP / TSSOP Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   49

/var/www/html/datasheet/sites/default/files/pdfhtml_dummy/1423_1424-html.html
background image

1°C Temperature Sensor with Hardware Thermal Shutdown

Datasheet

Revision 2.0 (08-10-12)

6

SMSC EMC1423/EMC1424

 

DATASHEET

List of Tables

Table 1.1 Part Selection  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7
Table 2.1 EMC1423 and EMC1424 Pin Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9
Table 3.1 Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11
Table 3.2 Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12
Table 3.3 SMBus Electrical Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13
Table 4.1 Protocol Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  14
Table 4.2 Write Byte Protocol  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  15
Table 4.3 Read Byte Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  15
Table 4.4 Send Byte Protocol  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  15
Table 4.5 Receive Byte Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  15
Table 4.6 Alert Response Address Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16
Table 5.1 Supply Current vs. Conversion Rate for EMC1423 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  18
Table 5.2 Supply Current vs. Conversion Rate for EMC1424 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  19
Table 5.3 SYS_SHDN Threshold Temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  20
Table 5.4 Temperature Data Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  26
Table 6.1 Register Set in Hexadecimal Order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  28
Table 6.2 Temperature Data Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  31
Table 6.3 Status Register  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  32
Table 6.4 Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  32
Table 6.5 Conversion Rate Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  33
Table 6.6 Conversion Rate  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  33
Table 6.7 Temperature Limit Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  34
Table 6.8 Scratchpad Register  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  35
Table 6.9 Therm Limit Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  36
Table 6.10 External Diode Fault Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  36
Table 6.11 Software Thermal Shutdown Configuration Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  37
Table 6.12 Hardware Thermal Shutdown Limit Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  38
Table 6.13 Channel Mask Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  38
Table 6.14 Consecutive ALERT Register  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  39
Table 6.15 Consecutive Alert / THERM Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  40
Table 6.16 Beta Configuration Registers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  40
Table 6.17 CPU Beta Values. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  41
Table 6.18 Ideality Configuration Registers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  41
Table 6.19 Ideality Factor Look-Up Table (Diode Model)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Table 6.20 Substrate Diode Ideality Factor Look-Up Table (BJT Model)  . . . . . . . . . . . . . . . . . . . . . . . . .  42
Table 6.21 High Limit Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  43
Table 6.22 Low Limit Status Register  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  43
Table 6.23 THERM Limit Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  44
Table 6.24 Filter Configuration Register  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  44
Table 6.25 Filter Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  45
Table 6.26 Product ID Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  45
Table 6.27 Manufacturer ID Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  45
Table 6.28 Revision Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  46
Table 9.1 Customer Revision History  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  51

/var/www/html/datasheet/sites/default/files/pdfhtml_dummy/1423_1424-html.html
background image

1°C Temperature Sensor with Hardware Thermal Shutdown

Datasheet

SMSC EMC1423/EMC1424

7

Revision 2.0 (08-10-12)

 

DATASHEET

Chapter 1 Block Diagram 

Figure 1.1 EMC1423/EMC1424 Block Diagram

1.1

  Part Selection

The EMC1423 and EMC1424 device configuration is highlighted below.

 

Table 1.1  Part Selection 

PART

NUMBER

SMBUS

ADDRESS

FUNCTIONALITY

PRODUCT

ID

EXTERNAL

DIODES

DIODE 1

DEFAULT

CONFIGURATION

DIODE 2

DEFAULT

CONFIGURATION

OTHER

EMC1423 - 1

100_1100b

2

Detect Diode w/ REC 

enabled

Detect Diode w/ REC 

enabled

Software program-

mable and mask-

able High Limits

Software program-

mable and mask-

able SYS_SHDN 

Limits

Hardware set 

SYS_SHDN Limit 

on External Diode 

1

23h

Internal 

Temp Diode

Switching

Current

Analog 

Mux

Internal

 Temperature 

Register

Di

gi

tal

 Mux

Digi

ta

l Mux

Limit Com

par

ator

Low Limit Registers

High Limit Registers

Conversion Rate Register

Interupt Masking

Status Registers

Configuration Register

SMBus Inter

face

ALERT

SYS_SHDN

SMCLK

SMDATA

DP1

DN1

V

DD

GND

EMC1423 / EMC1424

External 

Temperature 

Register(s)

ΔΣ ADC

SYS_SHDN Limit 

DP2

DN2

Anti-parallel 

diodes

/var/www/html/datasheet/sites/default/files/pdfhtml_dummy/1423_1424-html.html
background image

1°C Temperature Sensor with Hardware Thermal Shutdown

Datasheet

Revision 2.0 (08-10-12)

8

SMSC EMC1423/EMC1424

 

DATASHEET

Note 1.1

External 2 and external 3 channels have beta configuration hard wired to ‘0111b’ and REC 
enabled.

EMC1424 - 1

100_1100b

3

Detect Diode w/ REC 

enabled

Fixed 2N3904 in anti-

parallel diode configu-

ration 

Note 1.1

Software program-

mable and mask-

able High Limits

Software program-

mable and mask-

able SYS_SHDN 

Limits

Hardware set 

SYS_SHDN Limit 

on External Diode 

1

27h

Table 1.1  Part Selection (continued) 

PART

NUMBER

SMBUS

ADDRESS

FUNCTIONALITY

PRODUCT

ID

EXTERNAL

DIODES

DIODE 1

DEFAULT

CONFIGURATION

DIODE 2

DEFAULT

CONFIGURATION

OTHER

/var/www/html/datasheet/sites/default/files/pdfhtml_dummy/1423_1424-html.html
background image

1°C Temperature Sensor with Hardware Thermal Shutdown

Datasheet

SMSC EMC1423/EMC1424

9

Revision 2.0 (08-10-12)

 

DATASHEET

Chapter 2 Pin Description

 

Figure 2.1 EMC1423/EMC1424 Pin Diagram

Table 2.1  EMC1423 and EMC1424 Pin Description 

PIN NUMBER

NAME

FUNCTION

TYPE

1

VDD

Power supply

Power

2

DP1

External diode 1 positive (anode) 
connection

AIO

3

DN1

External diode 1 negative (cathode) 
connection

AIO

4

DP2 / DN3

External diode 2 positive (anode) 
connection / External Diode 3 
negative (cathode) connection for 
anti-parallel diodes

AIO

5

DN2/ DP3

External diode 2 negative (cathode) 
connection / External Diode 3 
positive (anode) connection for anti-
parallel diodes

AIO

6

GND

Ground

Power

7

SYS_SHDN

System Shutdown output signal - 
requires pull-up resistor which 
selects the Hardware Thermal 
Shutdown Limit

OD (5V)

8

ALERT

Active low digital ALERT output 
signal - requires pull-up resistor

OD (5V)

9

SMDATA

SMBus Data input/output - requires 
pull-up resistor

DIOD (5V)

10

SMCLK

SMBus Clock input - requires pull-up 
resistor

DI (5V)

SMDATA

SMCLK

ALERT

VDD

DP1

DN1

DN2 / DP3

DP2 / DN3

SYS_SHDN

GND

1

2

3

4

5

10

9

8

7

6

/var/www/html/datasheet/sites/default/files/pdfhtml_dummy/1423_1424-html.html
background image

1°C Temperature Sensor with Hardware Thermal Shutdown

Datasheet

Revision 2.0 (08-10-12)

10

SMSC EMC1423/EMC1424

 

DATASHEET

APPLICATION NOTE:  For the 5V tolerant pins that have a pull-up resistor (SMCLK, SMDATA, SYS_SHDN, and 

ALERT), the voltage difference between VDD and the pull-up voltage must never exceed 
3.6V. 

The pin types are described below:

Power - these pins are used to supply either VDD or GND to the device.

AIO - Analog Input / Output.

DI - Digital Input.

OD - Open Drain Digital Output.

DIOD - Digital Input / Open Drain Output.

Maker
Microchip Technology Inc.
Datasheet PDF Download